Monday 8 October |
|
08:30 meeting
|
Sunday 7 October |
- 06:30 fill 3135 lost to ALICE DIPOLE trip
- Fill 3135: 158 pb-1 in 10h3m
- 09:00 ATLAS have a gas leak in TRT detector - urgent access of ~1h required (LHC is anyway waiting for the injection kickers to cool down)
- PS RF expert (H. Damerau) increasing longitudinal blow-up to enhance
satellite population
- 11:04 MKI kicker temperature below threshold
- 11:00-11:40 Steering TI2/TI8. Some more losses at injection
(satellites?)
- 12:41 Loss of vacuum valve status in point 7 (Beam 2). Beam
dump during the squeeze. Access required.
- 15:23 Injecting after vacuum intervention
- 17:03 STABLE BEAMS #3138. Initial luminosity ~7.3x1033 cm-2s-1
- ALICE head-on luminosity reaching 1031 cm-2s-1 with enhanced
satellites after further adjustment in the PS in the morning. No need to
change filling scheme
|
09:00 meeting |
Saturday 6 October |
- 02:47 OP dump: ~187 pb-1 in 14.5 h. ~250 pb-1 in 24 h.
- 05:38 STABLE BEAMS #3134. Initial luminosities: 6.77x1033 cm-2s-1.
- 18:06 OP dump: fill 3134 177 pb-1 in 12h28m
- 20:28 back in Stable beams: fill 3135 – initial luminosity: 7.11x1033 cm-2s-1
- New record: Maximum Luminosity Delivered in one day 286.33 pb-1
|
09:00 meeting |
Friday 5 October |
- 00:42 End of access
- 02:51 STABLE BEAMS#3131 Initial luminosity 6.5x1033 cm-2s-1
- 06:19 UFO in sector 23 (BLMQI.31L3.B1I10_MQ) at 138% of dump
threshold End of fill #3131. 67 pb-1 in 4.5 h
- 08:16 Sector 81 trip RQ8.L1 (QPS noise) - Precycle
- 10:00 Injecting. Setting up of the damper gain modulation and BBQ
gated measurement on beam 1.
- 12:10 Colliding in IP1/5. Peak luminosity >7.5x1033 cm-2s-1.
- 12:18 STABLE BEAMS #3133. Initial luminosity 7.3x1033 cm-2s-1.
- 23:00 – 02:20 Bunch length variation
|
08:30 meeting |
Thursday 4 October |
- 01:40 Injecting probes
- 03:50 Stable beams fill 3129: Injected 1.63e11 ppb Initial luminosity: 6.72e33cm-2s-1
- Beams dumped at 08:25 – cryo: lost communication with main refrigerator point 4 - cold compressor stop
- Access for: installation of additional solenoids in point 8 close
to MKI8, CMS, BSRA, BRAN in point 8, CV checks in point 4 and 8, EL in
point 6 (UPS replacement), RF (instrumentation checks).
- 17:45 Cryo recovered
- 18:45 Start pre-cycle
- 19:50 TI2 steering
- 22:15 STABLE BEAMS#3130
- 22:35 Vacuum valves in undefined position in IR7 (B1). Beam dump. End
of fill 3130 after 20 mins (~6 pb-1)
- 23:49 access in point 7 for vacuum piquet. Replaced faulty
power supply for valve control crate.
|
08:30 meeting |
Wednesday 3 October |
- 03:05 dry dump as requested by the kicker piquet, all looks fine
- 03:30 – injecting physics beam
- 03:50 beams dumped at 450 GeV. ¨Trip of PC of RQTD.A34B1
- 05:45 Stable beams fill 3126. Initial luminosity: 7.16e33
cm-2s-1
- 12:13 Trip of RQF.A45. End of fill 3126. 115 pb-1 in 6.5
hours.
- 13:30-17:30 Access for: cryo
in triplet R2 in point 2, BSRT/BSRA, power converters, vacuum in point 4,
BRAN a,d diamond BLMs in point 8, ATLAS, TOTEM and QPS in point 5,
ventilation door in UJ33, QPS in SEctor 81
- 17:30 Pre-cycle
- 19:00-20:30: setting-up of the beam in the injectors, transfer line
steering
- 22:36 STABLE BEAMS #3128. Initial luminosity 6.4e33 cm-2s-1
- 22:51 Trip of RCBH29.R6B2 orbit corrector ==> SIS interlock. End of
fill #3128. 5 pb-1 in 15 mins.
-
|
08:30 meeting |
Tuesday 2 October |
|
08:30 meeting |
Monday 1 October |
- 03:13 beam dump by operation, exceptionally a natural end of fill
- injection delayed, undulator reset required
- Access: fault on inj kicker MKI8_D (electronics) - 300 V power supply
- Access: sublimation on new injection kicker - point 8
- 09:40 cycling
- 11:15 probes in, start 25 ns injection set-up/ transverse damper set-up
- 11:45 CMS - cryo problem - precautionary reduction to half normal solenoid current - recovery foreseen by midnight - perform full 25 ns injection set-up in shadow - should be able recuperate this time for physics on Thursday morning
- 17:30 Damper setting-up completed for both beams and planes
- 18:45 Beam 2: 72 bunches@25 ns injected
- Fill #3121 Good luminosities in spite of the reduced number of bunches, thanks to higher intensity (1.62x1011 at injection) and small emittances (Q20)
- 00:38 STABLE BEAMS CMS solenoid up just in time
|
08:30 meeting
|